| Product characteristics |
| Type of light |
red light |
| Laser protection class |
1 |
| Housing |
rectangular |
| Electrical data |
| Operating voltage [V] |
18…30 DC |
| Current consumption [mA] |
< 150 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Type of light |
red light |
| Wave length [Nm] |
650 |
| Typ. lifetime [h] |
50000 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Electrical design |
PNP |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (programmable) |
| Max. current load per output [mA] |
200 |
| Number of analog outputs |
1 |
| Analog current output [mA] |
4…20; (IEC 61131-2) |
| Max. load [Ω] |
250 |
| Analog voltage output [V] |
0…10; (IEC 61131-2) |
| Min. load resistance [Ω] |
5000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Monitoring range |
| Max. light spot width [mm] |
8 |
| Max. light spot height [mm] |
8 |
| Light spot dimensions refer to |
6 m |
| Background suppression [m] |
6…100 |
| Measuring/setting range |
| Measuring range [m] |
0.3…6; (white paper 200 x 200 mm 90 % remission) |
| Sampling rate [Hz] |
1…33 |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Smart Sensor: Sensor Identification; Binary Data Channel, Process Value; Sensor Diagnosis |
| SIO mode |
yes |
| Required master port class |
A |
| Process data analog |
2 |
| Process data binary |
2 |
| Min. process cycle time [ms] |
6 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| default |
812 |
|
| Operating conditions |
| Ambient temperature [°C] |
-10…60 |
| Protection |
IP 67 |
IFM optoelectronic switch O1D155
There are no reviews yet.